Resources
Contractor Resources
A practical guide for septic, wastewater, pump and electrical contractors choosing a Jackson Controls panel or alarm.
Simplex vs. duplex
| Simplex | Duplex | |
|---|---|---|
| Pumps | One | Two, in the same basin |
| How it runs | Pump starts and stops on float levels | Pumps alternate as lead; second pump comes on if the level keeps rising |
| Backup if a pump fails | No (alarm only) | Yes, the other pump keeps running |
| Typical use | Residential septic pump tanks, effluent and dosing tanks, small lift stations | Commercial, HOA and multi-building lift stations; anywhere redundancy is required |
See simplex control panels and duplex control panels.
Match the panel to the pump
The pump nameplate tells you most of what you need:
- Voltage: 120V, 240V or 480V
- Phase: single-phase or three-phase
- Horsepower or full-load amps (FLA): used to size the panel's components
We build simplex and duplex panels in 120V single-phase, 240V single-phase, 120/240V dual-voltage, 240V three-phase and 480V three-phase.
Alternator or PLC control (duplex)
- Standard alternator: an alternating relay switches the lead pump each cycle. Simple, proven, easy to service.
- PLC-based: a programmable controller runs the sequence. Choose this when the job needs extra timing, sequencing or special operating modes.
Not sure? Describe how the station should operate and we'll recommend one.
Alarm boxes: float or air
Our septic and ATU alarm boxes come in float or air options. Tell us what the system uses.
What to send for a fast quote
- Pump nameplate photo(s), or voltage, phase and HP/FLA
- Number of pumps and how they should run
- Float setup and alarm requirements
- Photos of the existing panel, if it's a replacement
- Drawings or spec sheets for engineered jobs
- Shipping state and quantity
Request a quote. You can attach photos and documents.
Documentation
Spec sheets, wiring diagrams and manuals will be posted on our product documentation page as they're approved. Need something now? Call (239) 271-2281 or email [email protected].
Ready to price a panel?
Tell us the pump, the voltage and the job. You don't need every spec to ask.